Hardware
NIST team reads transmon qubit with 35 GHz cavity at 99.2% fidelity
Akash V. Dixit of the U.S. National Institute of Standards and Technology in Boulder, Colorado, and colleagues coupled a 3.083 GHz transmon qubit to a 34.670 GHz aluminum cavity, a readout-to-qubit frequency ratio above 10. The team reports a measurement fidelity of 99.2% using 109 readout photons, with readout taking 780 nanoseconds. Floquet simulations indicate that at millimeter-wave frequencies the cavity drive mostly avoids drive-induced transitions between states in the transmon's Josephson potential well. The work is published in Physical Review Letters (2026), and a version is on arXiv.
Why it mattersReading a qubit often disturbs its state, and conventional transmons use readout resonators at 6 to 10 GHz. The authors say raising the readout frequency while keeping the transmon in the microwave range preserves the anharmonicity needed for fast gates and keeps thermal population minimal.}